PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.37.2.1.Exclusions
(1) Except as provided in Subsection 9.10.15. and Articles 9.37.2.4. and 9.37.3.1., buildings used or intended to be used
as seasonal recreational buildings need not comply with Sections 9.5. to 9.7. and 9.9. to 9.11.
(2) Flooring need not comply with Section 9.30., but tight-fitting floors shall be provided to support the live and dead
loads.
(3) Except as provided in Sentence (4), thermal insulation, vapour barrier, air barrier construction, interior finishes,
plumbing, heating, mechanical ventilation, air-conditioning and electrical facilities, need not be provided, but where any
of these are provided, they shall comply with the requirements of this Part.
(4) Where heating and air-conditioning are provided, Article 9.33.3.1. need not be complied with.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.