9.27.7.5.Fastening to Lath
(1) When lath is used with double-course application (See Sentence 9.27.5.1.(4)), it shall be spaced according to the
exposure and securely fastened to the framing.
(2) The butts of the under-course of the application referred to in Sentence (1) shall rest on the top edge of the lath.
(3) The outer course of the application referred to in Sentence (1) shall be fastened to the lath with nails of sufficient
length to penetrate through the lath.
(4) The butts of the shingles or shakes shall be so located that they project not less than 12 mm below the bottom edge
of the lath referred to in Sentence (1).
(5) If wood lath is not used, the butts of the under-course shingles or shakes of the application referred to in Sentence
(1) shall be located 12 mm above the butts of the outer course.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.