9.27.5.6.Expansion and Contraction
(1) Fasteners for metal cladding shall be positioned to permit expansion and contraction of the cladding.
(2) Fasteners for vinyl siding, insulated vinyl siding and polypropylene siding shall be installed in the centre of the slots
of the nail hem.
← Previous9.27.5.5. Fastener MaterialsNext →9.27.5.7. Penetration of Fasteners (See Note A-9.27.5.7.)
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.