9.27.2.1.Minimizing and Preventing Ingress and Damage
(1) Except where exterior walls are protected from precipitation or where it can be shown that precipitation ingress will
not adversely affect occupant health or safety, exterior walls shall be designed and constructed to
(a) minimize the ingress of precipitation into the assembly, and
(b) prevent the ingress of precipitation into interior space.
(See Note A-9.27.2.1.(1))
(2) Except where exterior walls are protected from specific mechanisms of deterioration, such as mechanical impact and
ultraviolet radiation, exterior walls shall be designed and constructed to minimize the likelihood of their required
performance being reduced to an unacceptable level as a result of those mechanisms.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.