PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.23.2.4.Connections to Preservative-Treated Wood
(1) Except as provided in Sentence (3), connectors in contact with preservative-treated wood shall be made of
(a) hot-dipped, zinc-coated galvanized steel with a coating weight not less than Z550 conforming to
ASTM A653 / A653M, “Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-
Coated (Galvannealed) by the Hot-Dip Process,”
(b) a material that provides an equivalent level of corrosion protection to that provided by the material described in
Clause (a), or
(c) stainless steel.
(2) Fasteners used to attach the connectors referred to in Sentence (1) shall be made of
(a) galvanized steel coated with zinc in accordance with ASTM A153 / A153M, “Standard Specification for Zinc
Coating (Hot-Dip) on Iron and Steel Hardware,” or
(b) a material that provides an equivalent level of performance and is compatible with the connector.
(3) Connectors and fasteners that are in contact with wood that has been treated with a disodium octaborate tetrahydrate
(SBX (DOT)) or zinc borate preservative and is installed in a dry interior environment are permitted to be made of
uncoated carbon steel. (See Note A-9.23.2.4.(3))
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.