9.23.2.2.Protection from Decay
(1) Ends of wood joists, beams and other members framing into masonry or concrete shall be treated to prevent decay
where the bottom of the member is at or below ground level, or a 12 mm air space shall be provided at the end and sides
of the member.
(2) Air spaces required in Sentence (1) shall not be blocked by insulation, vapour barriers or airtight materials.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.