PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.23.10.7.Stud Posts Built into Walls
(1) Except as provided in Sentences (2) and (3), stud posts shall be designed in accordance with Part 4.
(2) The number of studs in a wall directly below a girder truss or roof beam shall conform to Tables 9.23.10.7-A to
9.23.10.7.-D, provided
(a) the studs are fastened together to form a post in accordance with Sentence 9.17.4.2.(2),
(b) the wall is not less than 1.2 m long and sheathed on at least one side with plywood, OSB, waferboard or gypsum
sheathing, and
(c) the wall sheathing is fastened to the stud post with at least one row of fasteners conforming to Article 9.23.3.5. and
spaced not more than 150 mm o.c.
(See Note A-9.23.10.7.(2))
(3) The width of the stud post shall be not less than the width of the girder or beam that it supports.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.