9.21.3.8.Spaces Between Liners and Surrounding Masonry
(1) A space not less than 10 mm wide shall be left between a chimney liner and the surrounding masonry.
(2) The space required in Sentence (1) shall not be filled with mortar.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.