PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.21.3.10.Extension of Chimney Liners
(1) Chimney liners shall extend from a point not less than 200 mm below the lowest flue pipe connection to a point not
less than 50 mm or more than 100 mm above the chimney cap. See Note A-9.21.3.6.(2).)
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.