9.14.5.2.Sump Pits
(1) Where a sump pit is provided it shall be
(a) not less than 750 mm deep,
(b) not less than 0.25 m2 in area, and
(c) provided with a cover.
(2) Covers for sump pits shall be designed
(a) to resist removal by children, and
(b) to be airtight in accordance with Sentence 9.25.3.3.(7)
(3) Where gravity drainage is not practical, an automatic sump pump shall be provided to discharge the water from the
sump pit described in Sentence (1) into a sewer, drainage ditch or dry well.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.