PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.13.2.1.Required Dampproofing
(1) Except as provided in Sentence (4) and Article 9.13.3.1., where the exterior finished ground level is at a higher
elevation than the ground level inside the foundation walls, exterior surfaces of foundation walls below ground level shall
be dampproofed.
(2) Except as provided in Sentence (3) and Article 9.13.3.1., floors-on-ground shall be dampproofed.
(3) Floors in garages, floors in unenclosed portions of buildings and floors installed over granular fill in conformance
with Article 9.16.2.1. need not be dampproofed.
(4) Dampproofing in Sentence (1) is not required where the exterior surfaces of foundation walls below ground level are
waterproofed.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.