9.10.21.2.Separation of Sleeping Rooms
(1) Except for sleeping rooms within dwelling units, sleeping rooms in a building in a camp for housing of workers shall
be separated from each other and from the remainder of the building by a fire separation having not less than a 30 min
fire-resistance rating.
← Previous9.10.21.1. Requirements for Construction CampsNext →9.10.21.3. Floor Assemblies Between the First and Second St
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.