9.10.20.1.Windows or Access Panels Required
(1) Except as provided in Sentence (3), a window or access panel providing an opening not less than 1 100 mm high and
550 mm wide and having a sill height of not more than 900 mm above the floor shall be provided on the second and third
storeys of every building in at least one wall facing on a street if such storeys are not sprinklered.
(2) Access panels required in Sentence (1) shall be readily openable from both inside and outside or be glazed with
plain glass.
(3) Access panels required in Sentence (1) need not be provided in
(a) buildings containing only dwelling units where there is no dwelling unit above another dwelling unit, or
b) houses with a secondary suite.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.