PART 8 — SEWAGE SYSTEMSUpdated for the 2024 Ontario Building Code

8.7.2.3.Leaching Chambers within Leaching Beds

(1) Leaching chambers are permitted for use in conjunction with an absorption trench, shallow buried trench, filter bed or Type A dispersal bed. (2) Leaching chambers shall comply with the dimension requirements for either a Type I or Type II leaching chamber listed in Table 8.7.2.3. (3) Leaching chambers shall conform to the requirements of IAPMO PS 63, “Plastic Leaching Chambers”. (4) The header line and leaching chambers within a leaching bed shall be designed and constructed so that they can be detected by (a) magnetic means, (b) means of a 14 gauge TW solid copper light coloured plastic coated tracer wire, (c) means of a 12 gauge copper clad steel light coloured plastic coated tracer wire, or (d) other means of subsurface detection. Table 8.7.2.3. Leaching Chamber Dimensions Forming Part of Sentence 8.7.2.3.(2) Type of Leaching Chamber Width, mm Height, mm Type I 380 to 410 280 to 305 Type II 555 to 575 300 to 320

This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.