7.6.1.10.Mobile Home Water Service

(1) A water service pipe intended to serve a mobile home shall (a) be not less than NPS ¾, (b) terminate above ground, and (c) be provided with (i) a tamperproof terminal connection that is capable of being repeatedly connected, disconnected and sealed, (ii) a protective concrete pad, (iii) a means to protect it from frost heave, and (iv) a curb stop and a means of draining that part of the pipe located above the frost line when not in use.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.