PART 7 — PLUMBINGUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
7.5.5.2.Venting of Interceptors
(1) Every oil interceptor shall be provided with 2 vent pipes that
(a) connect to the interceptor at opposite ends,
(b) extend independently to open air,
(c) terminate not less than 2 m above ground and at elevations differing by at least 300 mm, and
(d) do not connect to each other or any other vent pipe.
(2) Adjacent compartments within every oil interceptor shall be connected to each other by a vent opening.
(3) Where a secondary receiver for oil is installed in conjunction with an oil interceptor, it shall be vented in accordance
with the manufacturer's recommendations, and the vent pipe shall
(a) in no case be less than NPS 1½,
(b) extend independently to open air, and
(c) terminate not less than 2 m above ground.
(4) The vent pipes referred to in Sentence (1) are permitted to be one NPS smaller than the largest connected drainage
pipe but not less than NPS 1¼, or can be sized in accordance with the manufacturer's recommendations.
(5) A vent pipe that serves an oil interceptor and is located outside a building shall be not less than NPS 3 in areas where
it may be subject to frost closure.
(6) Every grease interceptor inlet pipe shall be provided with a vent pipe
(a) within 1 500 mm of the inlet to the grease interceptor,
(b) not less than NPS 1½ for inlet pipes up to NPS 4, but not larger than NPS 2, and
(c) complete with a cleanout to provide cleaning of the vent pipe.
(7) Where an acid waste dilution tank is installed, it shall be provided with a vent pipe connected at the top of the tank
and that is sized in accordance with Article 7.5.7.7.
← Previous7.5.5.1. Venting of Sanitary Sewage SumpsNext →7.5.5.3. Venting of Drain Piping and Dilution Tanks for C
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.