PART 7 — PLUMBINGUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
7.3.4.1.Capability of Support
(1) Piping shall be provided with support that is capable of keeping the pipe in alignment and bearing the weight of the
pipe and its contents.
(2) Wall mounted fixtures shall be supported so that no strain is transmitted to the piping.
(3) Every floor or wall mounted water closet bowl shall be securely attached to the floor or wall by means of a flange
and shall be stable.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.