7.2.9.2.Solder and Fluxes
(1) Solders for solder joint fittings shall conform to ASTM B32, “Standard Specification for Solder Metal.”
(2) Solders and fluxes having a lead content in excess of 0.2% shall not be used in a potable water system.
(3) Fluxes for soldered joints shall conform to ASTM B813, “Standard Specification for Liquid and Paste Fluxes for
Soldering of Copper and Copper Alloy Tube.”
(4) Brazing alloys shall conform to ANSI/AWS A5.8M / A5.8, “Specification for Filler Metals for Brazing and Brazed
Welding,” BCuP range.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.