PART 7 — PLUMBINGUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
7.2.5.15.Polyethylene of Raised Temperature Tube and Fittings
(1) Polyethylene of raised temperature (PE-RT) tube and manufacturer-approved fittings used in hot and cold potable
water systems shall conform to CSA B137.18, “Polyethylene of raised temperature resistance (PE-RT) tubing systems for
pressure applications.” (See Note A-7.2.5.15.(1))
(2) The use of PE-RT tube shall conform to Table 7.2.5.15.
Table 7.2.5.15.
Permitted Uses of Polyethylene of Raised Temperature (PE-RT) Tube
Forming Part of Sentence 7.2.5.15.(2)
Plumbing Purposes(1)
Type of Drainage System Venting System Potable Water System
Tube Building
Aboveground Underground Above- Under- Under Outside
Sewer Cold Hot
inside building under building ground ground building building
PE-RT N N N N N P P P P
Notes to Table 7.2.5.15.:
(1) P = permitted and N = not permitted.
This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.
← Previous7.2.5.14. Polypropylene Pipe and FittingsNext →7.2.5.16. Cellular Core PVC Pipe and Fittings
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.