PART 7 — PLUMBINGUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
7.2.10.7B.Showers
(1) Except as provided for in Sentences (2) and (3), all valves supplying fixed location shower heads, shall be
individually pressure-balanced or thermostatic-mixing valves, conforming to ASME A112.18.1 / CSA B125.1,
“Plumbing Supply Fittings.”
(2) An individually pressure-balanced or thermostatic-mixing valve is not required for shower heads having a single
tempered water supply that is controlled by an automatic compensating valve conforming to CSA B125.3, “Plumbing
fittings.”
(3) Deck-mounted, hand-held, flexible-hose spray attachments are exempt from the thermal shock requirements of
Sentences (1) and (4).
(4) Pressure-balanced, thermostatic-mixing or combination pressure-balanced and thermostatic-mixing type valves shall
be
(a) capable of limiting thermal shock, and
(b) designed so that the outlet temperature does not exceed 49°C or equipped with high-limit stops which shall be
adjusted to a maximum hot water setting of 49°C.
← Previous7.2.10.7A. Temperature Control DevicesNext →7.2.10.7C. Linings and Coatings of Water Storage Tanks
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.