5.3.1.3.Location and Installation of Materials Providing Thermal Resistance
(1) Where a material required by Article 5.3.1.1. is intersected by a building assembly, penetrated by a high conductance
component or interrupted by expansion, control or construction joints, and where condensation is likely to occur at these
intersections, penetrations or interruptions, sufficient thermal resistance shall be provided so as to minimize condensation
at these locations.
(2) Materials providing required thermal resistance shall have sufficient inherent resistance to airflow or be positioned in
the assembly so as to prevent convective airflow through and around the material. (See Note A-5.3.1.3.(2))
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.