PART 4 — STRUCTURAL DESIGNUpdated for the 2024 Ontario Building Code

4.1.7.9.Full and Partial Wind Loading

(1) Except where the wind loads are derived from the combined C gCp values determined in accordance with Article 4.1.7.6., buildings and structural members shall be capable of withstanding the effects of the following loads: (a) the full wind loads acting along each of the 2 principal horizontal axes considered separately, (b) 75% of the wind loads described in Clause (a) but offset from the central geometric axis of the building by 15% of its width normal to the direction of the force to produce the worst load effect, (c) 75% of the wind loads described in Clause (a) but with both axes considered simultaneously, and (d) 56% of the wind loads described in Clause (a) but with both axes considered simultaneously and offset from the central geometric axis of the building by 15% of its width normal to the direction of the force. (See Note A-4.1.7.9.(1))

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.