PART 4 — STRUCTURAL DESIGNUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
4.1.5.10.Sway Forces in Assembly Occupancies
(1) The floor assembly and other structural elements that support fixed seats in any building used for assembly
occupancies accommodating large numbers of people at one time, such as grandstands, stadia and theatre balconies, shall
be designed to resist a horizontal force equal to not less than 0.3 kN for each metre length of seats acting parallel to each
row of seats, and not less than 0.15 kN for each metre length of seats acting at right angles to each row of seats, based on
the assumption that these forces are acting independently of each other.
← Previous4.1.5.9. Concentrated LoadsNext →4.1.5.11. Crane-Supporting Structures and Impact of Machin
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.