PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code

3.9.3.7.Fuel-Fired Appliances

(1) Where there is only one egress door from a portable classroom, a fuel-fired appliance shall be separated from the remainder of the classroom by a fire separation with a fire-resistance rating of not less than 45 min. (2) Except as provided in Sentences (3) and (4), if a portable classroom contains a fuel-fired appliance, the appliance shall be separated from the remainder of the classroom by a fire separation having a fire-resistance rating not less than (a) 1.5 h where the horizontal distance between portable classrooms is 1.5 m or less, and (b) 45 min where the horizontal distance between portable classrooms is more than 1.5 m. (3) If the horizontal distance between portable classrooms is 6 m or more, a fuel-fired appliance need not be separated from the remainder of the classroom by a fire separation provided (a) there is not more than one appliance per portable classroom, and (b) the appliance is located not less than 4.5 m from an egress doorway or an exit from the portable classroom. (4) Fuel-fired appliances with sealed combustion located in a portable classroom are not required to be separated from the remainder of the classroom (a) if there are not more than four portable classrooms in a group, and (b) if the appliance is located not less than 4.5 m from an egress doorway or an exit from the portable classroom.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.