3.8.3.9.Water Closets (See Note A-3.8.3.9.)
(1) A water closet described in Clause 3.8.3.8.(1)(d) or (10)(c) or 3.8.3.12.(1)(d) shall
(a) be equipped with a seat located at not less than 430 mm and not more than 485 mm above the finished floor,
(b) flush automatically or be equipped with a flushing control that
(i) is located between 500 mm and 900 mm above the finished floor,
(ii) is operable from the transfer side, and
(iii) is operable using a closed fist and with a force of not more than 22.2 N, and
(c) be equipped with a back support where there is no seat lid or tank. (See Note A-3.8.3.9.(1)(c))
(See Note A-3.8.3.9.(1))
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.