PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.8.3.7.Assistive Listening Systems
(1) In buildings of assembly occupancy, all classrooms, auditoria, meeting rooms and theatres with an area of more than
100 m2 shall be equipped with an assistive listening system encompassing the entire seating area. (See Note A-
3.8.3.7.(1))
(2) In each location where information, goods or services are provided to the public at service counters in buildings of
assembly occupancy, at least one of the service counters shall be equipped with:
(a) an assistive listening system or adaptive technology, and
(b) an amplification system, where there is a barrier to communication, such as a glass screen.
(See Note A-3.8.3.7.(2))
(3) Assistive listening systems or adaptive technologies required by Sentence (2) shall provide for the clear
communication required for the exchange of information, goods, and services.
← Previous3.8.3.6. Wheelchair Spaces and Adaptable SeatingNext →3.8.3.8. Water Closet Stalls and Enclosures
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.