PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.2.2.62.Group D, up to 3 Storeys
(1) A building classified as Group D is permitted to conform to Sentence (2) provided
(a) it is not more than 3 storeys in building height, and
(b) it has a building area not more than the value in Table 3.2.2.62.
Table 3.2.2.62.
Maximum Building Area, Group D, up to 3 Storeys
Forming Part of Sentence 3.2.2.62.(1)
Maximum Area, m2
No. of Storeys
Facing 1 Street Facing 2 Streets Facing 3 Streets
1 4 800 6 000 7 200
2 2 400 3 000 3 600
3 1 600 2 000 2 400
(2) The building referred to in Sentence (1) is permitted to be of combustible construction or noncombustible
construction used singly or in combination, and
(a) floor assemblies shall be fire separations and, if of combustible construction, shall have a fire-resistance rating not
less than 45 min,
(b) mezzanines shall have, if of combustible construction, a fire-resistance rating not less than 45 min,
(c) roof assemblies shall have, if of combustible construction, a fire-resistance rating not less than 45 min, except that
in a building not more than 1 storey in building height, the fire-resistance rating is permitted to be waived provided
the roof assembly is constructed as a fire-retardant-treated wood roof system conforming to Article 3.1.14.1., and
the building area is not more than
(i) 2 400 m2 if facing one street,
(ii) 3 000 m2 if facing 2 streets, or
(iii) 3 600 m2 if facing 3 streets, and
(d) loadbearing walls, columns and arches supporting an assembly required to have a fire-resistance rating shall
(i) have a fire-resistance rating not less than 45 min, or
(ii) be of noncombustible construction.
This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.
← Previous3.2.2.61. Group D, up to 4 Storeys, SprinkleredNext →3.2.2.63. Group D, up to 3 Storeys, Sprinklered
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.