3.2.2.14.Rooftop Enclosures
r1 (1) A rooftop enclosure for elevator machinery or for a service room shall be constructed in accordance with the type of
construction required by Articles 3.2.2.20. to 3.2.2.93.
(2) A rooftop enclosure for elevator machinery or for a service room, not more than 1 storey high, is not required to
have a fire-resistance rating.
r1 (3) A rooftop enclosure for a stairway shall be constructed in accordance with the type of construction required by
Articles 3.2.2.20. to 3.2.2.93.
(4) A rooftop enclosure for a stairway need not have a fire-resistance rating nor be constructed as a fire separation.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.