PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.10.2.5.Exit Requirements
(1) Except as provided in Sentences (2) and (3), the requirements in Section 3.4. shall apply.
(2) The clear width of an exit stair shall be not less than 1 100 mm.
(3) Exit doors from rental spaces are not required to swing on a vertical axis provided
(a) the area of the rental space is not more than 50 m 2, and
(b) the travel distance within the rental space is not more than 10 m.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.