PART 2 — RESERVEDUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
2.2.8.8.Pesticide Storage Areas
(1) In addition to the requirements of Article 2.2.8.7., pesticide storage areas in farm buildings shall be designed in
conformance with this Article.
(2) Pesticide storage areas shall be
(a) ventilated with outdoor air in accordance with Subsection 2.4.2. by dedicated natural or mechanical means at a rate
sufficient to prevent the accumulation of dangerous goods classified as toxic or flammable gases,
(b) accessible only from the outdoors, and
(c) secured against unauthorized entry.
(3) Floors of pesticide storage areas shall
(a) be constructed of concrete or other impervious material,
(b) not have a floor drain, and
(c) be provided with a curb at the perimeter of the storage area that is
(i) designed to contain accidental spillage of the largest container in the storage area, and
(ii) not less than 50 mm high.
(4) Pesticide storage areas shall be separated from
(a) food, feed and water supplies,
(b) other occupancies by a fire separation having a fire-resistance rating not less than 1 h, and
(c) other buildings by a limiting distance not less than 6 m.
← Previous2.2.8.7. Dangerous Goods StorageNext →2.2.8.9. Hazardous Extraction Operation Involving Cannabi
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.