2.2.8.2.Exhaust Ventilation and Explosion Venting

(1) Except as provided in Sentence (3), an exhaust ventilation system designed in conformance with the appropriate requirements of Section 2.4. shall be provided in a farm building or part of a farm building in which dust, fumes, gases, vapours or other impurities or contaminants have the potential to create a fire or explosion hazard. (2) Except as provided in Sentence (3), farm buildings shall comply with Sentence 3.3.1.21.(3). (3) Farm buildings housing livestock with a below-floor storage area for liquid manure need not comply with Sentences (1) and (2), provided they comply with Article 2.2.8.3. (See Note A-2.2.8.2.(3))

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.