PART 2 — RESERVEDUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
2.2.6.2.Egress Doorways
(1) Except as provided in Sentence (2), at least one egress doorway shall be provided from every room.
(2) A minimum of 2 egress doorways located so that one doorway could provide egress from the room as required by
Article 2.2.6.3. if the other doorway becomes inaccessible to the occupants due to a fire originating in the room, shall be
provided for every room
(a) that is used for a Group G, Division 1 major occupancy, other than one housing livestock with a below-floor storage
area for liquid manure, where the area of the room is more than
(i) 15 m2, in a floor area that is not sprinklered throughout, or
(ii) 30 m2, in a floor area that is sprinklered throughout,
(b) in a floor area that is not sprinklered throughout and contains a Group G, Division 1 major occupancy housing
livestock with a below-floor storage area for liquid manure or a Group G, Division 2 or 3 major occupancy, where
(i) the area of the room is more than 200 m2, or
(ii) the travel distance within the room to the nearest egress doorway is more than 15 m, or
(c) in a floor area that is sprinklered throughout and contains a Group G, Division 1 major occupancy housing
livestock with a below-floor storage area for liquid manure or a Group G, Division 2 or 3 major occupancy, where
(i) the area of the room is more than 300 m2, or
(ii) the travel distance within the room to the nearest egress doorway is more than 25 m.
(3) Where 2 egress doorways are required by Sentence (2), they shall be placed at a distance from one another equal to
or greater than one third of the maximum overall diagonal dimension of the area to be served, measured as the shortest
distance that smoke would have to travel between the nearest required egress doorways.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.